Short answer: for a three-day outage, decide first what you are really backing up, because the answer changes by a factor of nine. In our math, staying connected (router, phone and laptop charging, four LED lights) takes about 2.8 kWh from the battery over three days. Adding a refrigerator takes it to about 8.6 kWh. Adding a gas furnace blower too is about 24.7 kWh, which only a fully expanded home-backup unit gets near (our furnace guide notes the Anker SOLIX F3800 Plus reaches about 26.9 kWh with six add-on batteries).
- Stay-connected tier (about 2.8 kWh): a 1 kWh station covers about 1.1 days, a 2 kWh station about 2.2 days, and the ~3.6–4.1 kWh home-backup units about 3.9–4.5 days, with no sun at all.
- Fridge tier (about 8.6 kWh): even the largest stations in our dataset (about 4 kWh) cover only 1.3–1.4 days alone. Three days takes expansion batteries, solar, a smaller fridge budget, or a safely run generator.
- Solar helps most in the middle of winter days, not nights. In our model of a typical December in Minneapolis, 400 W of panels put about 980 Wh a day into a battery on a median day, enough to carry the whole stay-connected tier. In the worst three-day gray stretch it was only about 315 Wh in total.
- Plan the battery for the gray days and treat the panels as a bonus. That is the same rule as in our cloudy-day guide, applied to a specific three-day list.
- The calm version of the plan: pick a tier, charge everything before the storm, cut loads on day one, and keep a non-electric backup for heat and food.
Safety first. This is planning math, not electrical or medical advice. Never run a generator, grill, or camp stove indoors, and keep generators at least 20 feet from windows. Never backfeed a house through a wall outlet; hardwired circuits (furnace, well pump) need a transfer switch or inlet installed by a licensed electrician (transfer switch guide). If a medical device depends on power, talk to your provider about an outage plan (CPAP example). Never heat a home with a gas stovetop or oven.
We haven’t tested any of these stations through a three-day outage. The load numbers come from our published appliance estimates and examples, the station specs from each brand’s official page, and the sun numbers from NLR’s PVWatts model. Everything is labeled where it appears.
What Ready.gov says to plan for
Ready.gov’s power outage page tells you to take an inventory of the items you need that rely on electricity, plan for batteries and other alternative power sources, keep a portable charger or power bank, and have flashlights for every household member. It says a refrigerator keeps food cold for about four hours and a full freezer for about 48 hours if you keep the doors closed, and to throw food out if its temperature is 40°F or higher. Its emergency kit list asks for “at least a several-day supply” of non-perishable food and water, a battery-powered or hand-crank radio, a NOAA Weather Radio, flashlights, extra batteries, and a phone with chargers and a backup battery. For winter storms, its winter weather page says to gather supplies in case you need to stay home for several days without power.
Ready.gov says “several days,” not a number. We use three days (72 hours) here as a round planning unit, and you can scale our tables up or down from it.
Step 1: Pick your tier
Here are three example load lists. Watts and hours come from our runtime calculator defaults, which come from published appliance ranges; the fridge uses the 600 kWh-a-year EnergyGuide example from our refrigerator guide, and the furnace uses the DOE blower example from our furnace guide. Battery energy is the wall-outlet energy divided by our stated 0.85 inverter efficiency (methodology).
| Tier | What’s in it | Outlet energy per day | Battery energy per day | Battery energy, 3 days |
|---|---|---|---|---|
| A. Stay connected | Router/modem (15 W, 24 h = 360 Wh), phone and laptop chargers (60 W, 3 h = 180 Wh), 4 LED bulbs (12 W each, 5 h = 240 Wh) | 780 Wh | 918 Wh | 2,753 Wh |
| B. A + refrigerator | Tier A plus a fridge using 600 kWh/yr (about 1,644 Wh a day) | 2,424 Wh | 2,852 Wh | 8,555 Wh |
| C. B + gas furnace blower | Tier B plus the DOE example blower (382 W at 50% duty, 4,584 Wh a day; draft inducer and controls not included) | 7,008 Wh | 8,245 Wh | 24,734 Wh |
Appliance values are typical estimates and our duty-cycle assumptions, not measurements of your home. Swap in your own numbers with the runtime calculator. A hardwired furnace needs a licensed electrician’s transfer switch or inlet.
Two things to notice. The fridge is the single biggest piece of Tier B, but it is also the load with the most flexibility, because Ready.gov’s four-hour and 48-hour numbers tell you how long food holds with the doors closed. And Tier C is not a three-day plan for a portable station at all; the furnace guide explains why a portable battery is a bridge there, not a solution.
Step 2: What a battery alone covers
Days of each tier from a full battery with no sun at all (capacity ÷ battery energy per day), using each model’s rated capacity from its official page (spec dataset checked Oct 29, 2026):
| Station | Capacity | Tier A (stay connected) | Tier B (+ fridge) |
|---|---|---|---|
| EcoFlow DELTA 3 Plus | 1,024 Wh | 1.1 days | 0.4 days |
| Anker SOLIX C1000 Gen 2 | 1,024 Wh | 1.1 days | 0.4 days |
| Jackery Explorer 1000 v2 | 1,070 Wh | 1.2 days | 0.4 days |
| BLUETTI AC180 | 1,152 Wh | 1.3 days | 0.4 days |
| Jackery Explorer 2000 v2 | 2,042 Wh | 2.2 days | 0.7 days |
| Jackery HomePower 3600 Plus | 3,584 Wh | 3.9 days | 1.3 days |
| Anker SOLIX F3800 Plus | 3,840 Wh | 4.2 days | 1.3 days |
| EcoFlow DELTA Pro 3 | 4,096 Wh | 4.5 days | 1.4 days |
Capacity figures are rated, not usable-in-practice; real runtime depends on temperature, the battery’s low-charge cutoff, and what you actually plug in. For the three-day fridge tier you need roughly 8.6 kWh of battery or its equivalent, which means expansion batteries on a home-backup unit (see our expansion battery chart), solar, a lower fridge budget, or another source. Our flagship comparison and cost per kWh table show what each extra kilowatt-hour costs.
Step 3: What solar adds in December
We reuse the PVWatts V8 runs from our cloudy-day guide: a south-facing panel at a 35° tilt, typical-year weather, and our 0.85 factor for panel heat, wiring, and charge-controller losses. The table shows 400 W of panels (two 200 W-class panels), in December:
| City | Median December day, into battery | 3 median days | Worst 3-day gray stretch (Nov–Feb) | Panel watts to cover Tier A on a median December day |
|---|---|---|---|---|
| Phoenix | ~2,120 Wh | ~6,350 Wh | ~3,050 Wh | ~170 W |
| Denver | ~1,610 Wh | ~4,830 Wh | ~1,610 Wh | ~230 W |
| Atlanta | ~1,510 Wh | ~4,540 Wh | ~810 Wh | ~240 W |
| Minneapolis | ~980 Wh | ~2,930 Wh | ~315 Wh | ~375 W |
| Chicago | ~780 Wh | ~2,350 Wh | ~320 Wh | ~470 W |
| Seattle | ~420 Wh | ~1,250 Wh | ~355 Wh | ~880 W |
Model results from NLR (formerly NREL) PVWatts V8 hourly runs with NSRDB typical-year weather (run Oct 29, 2026); our arithmetic in research/sources-2026-11-03/outage-3day-math.py. “Median day” is the middle day of the month by sun hours, so three median days in a row is a hopeful case, not a forecast. Real winter storms often mean the gray stretch.
Reading it for Tier A (918 Wh a day from the battery side, 2,753 Wh over three days):
- In the sunnier cities, 400 W of panels can cover the stay-connected tier even in December if you get ordinary days, with plenty to spare in Phoenix, Denver, and Atlanta.
- In the gray northern cities, the worst three days gave only about 315–355 Wh in total. That’s about 11–13% of the 2,753 Wh Tier A needs over three days. The battery has to do almost all of it.
- Tier B on solar alone is out of reach for portable kits in the North in December. The fridge tier needs about 1,170 W of panels for a median Minneapolis day, and on a typical overcast day the numbers are several times higher (our cloudy-day guide has the table).
Putting battery and solar together (Minneapolis, Tier A and B)
Net energy the battery must supply over three days (3-day need minus solar into the battery), compared with what a station holds. It is a simple three-day total; it ignores a full battery turning panels away on a sunny day and any low-charge cutoff.
| Plan | Tier A (2,753 Wh) | Tier B (8,555 Wh) |
|---|---|---|
| No solar | 2,753 Wh | 8,555 Wh |
| 400 W, three median December days | 0 Wh (solar covers it) | 5,621 Wh |
| 400 W, worst 3-day gray stretch | 2,438 Wh | 8,240 Wh |
| 800 W, three median December days | 0 Wh | 2,687 Wh |
| 800 W, worst 3-day gray stretch | 2,123 Wh | 7,925 Wh |
The pattern: with a ~3.6–4.1 kWh home-backup station, Tier A is covered in every row, even with no sun (3,584–4,096 Wh against 2,753 Wh). A ~1 kWh station covers Tier A only if you get a decent amount of sun or you trim the list (for example, phones and router only, lights off). A 2 kWh station covers Tier A for about 2.2 days alone, so over three days it needs roughly 700 Wh from solar or a trimmed list; in the worst gray stretch it falls about 80–400 Wh short unless you cut loads. Tier B needs the big stations, expansion batteries, and reasonably sunny days, or a plan that doesn’t run the fridge from the battery around the clock.
An owner reading, for scale: on a clear Oct 29, the StormWatts owner’s four 200 W panels (800 W) took a Jackery Explorer 2000 Plus from 17% to 100% by about 4:45 PM, roughly 1,700 Wh by our arithmetic (owner-tested write-up). That’s a late-October sunny day in Minnesota; December’s low sun gives less (winter solar guide).
Step 4: A calm three-day routine
None of this needs to be dramatic. Here is a simple routine built on the numbers above:
- Before the storm: charge every station, power bank, and phone to full. Put the panels, cables, and a clear spot for them where you can reach them in snow, and plan to keep the station itself indoors (what rain and snow ratings cover). If a storm watch is issued, Ready.gov says watches are usually issued 12 to 48 hours ahead, so that is your window.
- Day 1: unplug or switch off everything that isn’t on your tier list. Keep fridge and freezer doors closed, and use a thermometer so you know when food is nearing 40°F.
- Fridge budget: if you can’t run it around the clock, the choice is yours to make with a thermometer, not a rule from us. The 600 kWh-a-year example fridge averages about 69 W, so it is a much smaller load than most people expect, but it adds up over three days.
- Each sunny hour: get panels out, aimed, and clear of snow and shade (re-aiming guide, shade guide). Run higher loads, such as laptops, during the middle of the day so you use solar directly (appliances while charging).
- Nights and gray stretches: drop to Tier A, and use a battery-powered or hand-crank radio and flashlights for the rest. If it is dangerously cold, go to a warming location with power rather than risking carbon monoxide at home, as Ready.gov advises.
- After: disconnect appliances before power returns, since Ready.gov warns about surges, and recharge and store your station per its manual.
What this plan doesn’t cover
- Heating. A space heater uses 750–1,500 W, so a ~1 kWh battery lasts under an hour. Do not plan around one; see the furnace guide.
- Well pumps, sump pumps, and medical devices. Each has its own guide: sump pump, CPAP, and the sizing guide.
- Your exact home. Our appliance numbers are estimates, our weather is a typical year in six cities, and your fridge, router, and chargers will differ. Use the calculator and the free power outage checklist.
- Non-electric basics. Water, food, medicines, blankets, and a radio matter as much as the battery; start from Ready.gov’s kit list.
Brand-matched 200 W-class panels for the stations above are compared in our best solar panels for each power station guide: Jackery SolarSaga 200W, EcoFlow NextGen 220W Bifacial, BLUETTI 200W (SP200L), and Anker SOLIX PS200 Bifacial. Prices change often, so check the brand’s page for today’s price.
Sources
- Ready.gov, Power Outages (inventory of electric needs, alternative power, fridge ~4 hours, full freezer ~48 hours, 40°F rule, generator outdoors and 20 feet from windows, surge warning), Build a Kit (“at least a several-day supply” of food, radio, flashlights, phone chargers and backup battery), and Winter Weather (stay-home supplies, watch lead time 12 to 48 hours, carbon monoxide and gas oven warnings) (all checked Nov 3, 2026)
- FoodSafety.gov, Food safety during a power outage, as cited in our refrigerator guide
- Appliance wattage estimates: Champion Power Equipment, Generator Wattage Chart (router, chargers, LED, furnace ranges; checked Oct 7, 2026), via our
appliances.json; duty cycles and the 600 kWh/yr fridge and DOE 382 W blower examples as in our refrigerator and furnace guides - Station capacities: official pages for each model linked in our cost per kWh comparison (dataset checked Oct 29, 2026)
- NLR (formerly NREL), PVWatts V8 API documentation and hourly runs for Minneapolis, Seattle, Chicago, Atlanta, Denver, and Phoenix (1 kW, standard module, fixed open rack, south-facing, 35° tilt, 14% losses, NSRDB typical-year weather; run Oct 29, 2026), summarized in our cloudy-day guide
- StormWatts model:
research/sources-2026-11-03/outage-3day-math.py(tiers, station days, city and combined tables) and the Oct 29cloudy-math.py. Assumptions: 0.85 inverter efficiency; 0.85 solar charge-path factor; 3 days = 72 hours.