Short answer: a shadow costs a portable solar panel far more power than its size suggests, and the best fix is almost always moving the panels, not rewiring them. When you can’t avoid shade, the right wiring depends on the shape of the shadow:
- A shadow across one end of a panel (fence top, post, branch, the edge of the house): in our model, two panels in series held up better than two in parallel. Series kept about 306–340 W of 415 W, and parallel kept about 230–280 W.
- One whole panel in shade (sitting under a tree canopy or in a building’s shadow while the other is in sun): parallel held up better, about 250–310 W vs 190–230 W in series.
- On a low-voltage input, partial shade can drop a panel or a parallel bank below the station’s working window. On a Jackery Explorer 2000 Plus input, that’s under 17.5 V (current cut to 8 A) or under 11 V (no charging). Series keeps voltage headroom, so it degrades more gently.
- Keep panels that share the same shade on the same input, and use a separate input (each with its own charge controller where the brand says so) for panels in a different spot.
These are model results from published specs, not measurements, and the assumptions are listed below. Brands’ own advice is simpler: avoid shade entirely.
Safety first. Don’t exceed your station’s input voltage, and keep cold-weather margin (series vs parallel guide). Never backfeed a house through a wall outlet; hardwired circuits need a transfer switch or inlet installed by a licensed electrician (transfer switch guide). This page is research, not electrical advice.
We haven’t tested panels in shade. Specs and quotes come from each brand’s official pages and manuals (checked Oct 26, 2026), and the background on bypass diodes comes from a National Renewable Energy Laboratory paper. The wattages below come from our own simple electrical model and are labeled as such. The StormWatts owner uses a Jackery Explorer 2000 Plus with a Battery Pack 2000 Plus, four SolarSaga 200 panels, and Jackery’s solar series connector. The model figures here don’t come from that setup, but the owner’s owner-tested day of solar caught a real example: a bare tree cut input from 559 W to 338 W in three minutes, then to 138 W.
What the brands say about shade
Every brand we checked tells you to keep panels out of shade, and none publishes how much power its folding panels keep in partial shade:
- Jackery (SolarSaga 200W FAQ): when testing the panel, “make sure there is no shadow cast on the panel.” Its SolarSaga 200W manual (JS-200D) says not to place the panels “in trees, buildings or other shaded areas.”
- EcoFlow (400W panel manual): “The surface of the solar panel should not be shaded during use. Shading caused by shadows, foreign objects and glass can all greatly reduce power output.”
- Anker SOLIX (PS200 and PS400 FAQs): output “varies with sunlight intensity, panel orientation, and angle,” and you should test “under full, [un]obstructed sunlight.”
- BLUETTI (SP200L FAQ): lists “shading” among the factors that limit a panel’s output.
- Renogy sells a rigid “anti-shading” panel, the ShadowFlux 200W, and still recommends “aiming for over half of the panel surface to be in direct sunlight” (more on it below).
Why a small shadow costs so much
A solar panel is a chain of cells wired in series, so every cell carries the same current. A cell in shade can’t carry that current, and it holds back the cells in its chain. To keep a shaded cell from overheating, panels have bypass diodes, each one wired across a group of cells. When a group is shaded, its diode switches on and current flows around it. You lose that whole group’s voltage, but the rest of the panel keeps working.
NREL’s study of partially shaded systems (Deline, 2009) puts numbers on it:
- Bypass diodes are typically “placed across 12-18 cells.”
- In its worst case, “shading half of one cell negates all the power produced by the 18 cells in that bypass diode group,” so the power lost is like removing an area “36 times the shadow’s actual size.”
That’s why a single leaf, a strap, or a fence-top shadow along one edge can cut output by a third or a half. None of the four big portable-power brands publishes how many bypass-diode groups its folding panels have, so you can’t tell from the spec sheet how a given panel will handle shade.
Series vs parallel in shade: our model
To see how wiring changes things, we modeled two panels with the current SolarSaga 200W’s published ratings (22 V open-circuit, 12.5 A short-circuit, 18 V / 11.5 A working point; checked Oct 26, 2026, $379 that day). Because Jackery doesn’t publish the panel’s bypass-diode layout, we ran it two ways: 2 or 3 diode groups per panel. The ranges below cover both. We also assumed the station’s charge controller finds the best operating point even when shade creates more than one power peak. No brand we checked says whether its controller does a full sweep, so real results could be lower.
“No limits” is the panels alone. “Explorer 2000 Plus input” applies that input’s published limits: 11–17.5 V at 8 A max, 17.5–60 V at 12 A max.
| Shade (our model) | Series, no limits | Parallel, no limits | Series on one Explorer 2000 Plus input | Parallel on one Explorer 2000 Plus input |
|---|---|---|---|---|
| Full sun, both panels | 415 W | 415 W | 415 W | 244 W |
| One end of one panel shaded (one diode group at 10% light) | 306–340 W | 230–278 W | 306–340 W | 223–224 W |
| One whole panel in light shade (50% light) | 228 W | 312 W | 228 W | 237 W |
| One whole panel in deep shade (20% light) | 190–196 W | 248 W | 178–192 W | 227 W |
| One end of both panels shaded | 196–265 W | 196–265 W | 192–265 W | 46–103 W |
StormWatts model, not measurements: a simple single-diode panel model fitted to Jackery’s published ratings at 77°F cell temperature, with ideal bypass diodes. Script: research/sources-2026-10-26/shade-math.py. The full-sun parallel figure (244 W) is a bit higher than the simpler 18 V × 12 A ≈ 216 W estimate in our series vs parallel guide, because here the station can move up the panel’s curve to a higher voltage when it limits current. Either way, parallel wastes about 40–50% of this pair on one input.
What the model shows:
- Edge shadows favor series. When a bypass diode switches on, the panel loses voltage, not current. In series, the other panel’s voltage still adds on top, so the string loses only the shaded group’s share. In parallel, both panels have to run at the same voltage, so the shaded panel’s lower voltage drags the pair to a worse operating point.
- Whole-panel shade favors parallel. When an entire panel gets less light, its current drops. In series, the string either runs at that low current or bypasses the whole panel. In parallel, the shaded panel just adds less current while the sunny one runs normally.
- Low-voltage inputs make parallel shade worse. With both panels’ ends shaded, each panel’s voltage sags toward or below the 11 V minimum and 17.5 V band edge, so the parallel pair collapsed to 46–103 W in the model while the series pair stayed above 190 W.
These results apply to 18 V-class panels on a 60 V input. With 48 V-class panels such as the EcoFlow 400W or Anker PS400, you usually can’t put two in series on a 60 V station anyway, so the choice is one panel per input or parallel within the brand’s current limits (series vs parallel guide).
Separate inputs beat clever wiring
The cleanest way to limit shade loss is to keep a shaded panel from sharing a charge controller with a sunny one:
- EcoFlow DELTA 3 Plus: EcoFlow lists “500W MPPT × 2” on the product page (DELTA 3 Plus).
- Anker SOLIX F3800 Plus: “dual MPPT,” “2 × 165VDC MPPT Input” on the product page (F3800 Plus). Anker’s design guide (checked Oct 24, 2026) says each input has its own MPPT and “can only connect to one solar array.”
- EcoFlow DELTA Pro 3: separate High-PV and Low-PV inputs with different voltage windows (DELTA Pro 3).
- Jackery Explorer 2000 Plus: two DC inputs with the limits above (Explorer 2000 Plus). Jackery’s page doesn’t say whether each input has its own tracker, and its manual (checked Oct 24, 2026) requires the same panel type and count on both inputs.
- Jackery SolarSaga 500X / Explorer 500X kit: six 85 W panels in parallel; Jackery says “each panel works independently” for “a partially shaded cabin” (SolarSaga 500X).
The rule of thumb: group panels by exposure. Panels in the same spot (same shade, same hours) go on the same input. A second spot goes on the second input. In our model, putting one shaded and one sunny panel on separate Explorer 2000 Plus inputs gave 231–310 W with an edge shadow and 248–312 W with whole-panel shade. That’s close to the better wiring in every case, but on the 2000 Plus it means one 18 V panel per input, which falls into the 8 A band once the cells heat up (why). With four panels, the practical version is two series pairs, each pair side by side so both panels share the same light.
How far to keep panels from fences, houses, and trees
Shadows are longest in winter and early and late in the day. Here’s how long a shadow is for each foot of obstacle height, from standard sun-position equations (the same math NOAA’s solar calculator uses), at local solar time:
| City | Dec 21: 9 AM / noon / 3 PM | Mar 20 or Sep 22: 9 AM / noon / 3 PM | Jun 21: 9 AM / noon / 3 PM |
|---|---|---|---|
| Minneapolis, MN | 5.5× / 2.5× / 5.5× | 1.8× / 1.0× / 1.8× | 0.9× / 0.4× / 0.9× |
| Denver, CO | 4.0× / 2.0× / 4.0× | 1.6× / 0.9× / 1.6× | 0.9× / 0.3× / 0.9× |
| Atlanta, GA | 3.0× / 1.6× / 3.0× | 1.4× / 0.7× / 1.4× | 0.9× / 0.2× / 0.9× |
| Houston, TX | 2.5× / 1.3× / 2.5× | 1.3× / 0.6× / 1.3× | 0.9× / 0.1× / 0.9× |
Our math (shadow length = obstacle height ÷ tan(sun elevation)). The 9 AM and 3 PM shadows point northwest and northeast, so the reach straight north of an obstacle due south is shorter: about 4.2× in Minneapolis and 1.8× in Houston on Dec 21.
In practice, for a 6 ft privacy fence due south of your panels on Dec 21:
- Minneapolis: the noon shadow reaches about 15 ft, and the 9 AM shadow reaches about 25 ft north of the fence.
- Houston: about 8 ft at noon and 11 ft at 9 AM.
- A 30 ft tree due south shades about 76 ft at noon in Minneapolis in late December, and about 40 ft in Houston.
So in a northern winter outage, panels often need to be in the middle of the yard or on a south-facing deck rather than “just in front of the fence.” Summer is forgiving: at noon in late June, a 6 ft fence casts only about 2.3 ft of shadow in Minneapolis. For winter sun hours and tilt, see our winter solar charging guide.
Shade-tolerant panels: what Renogy claims
Renogy’s ShadowFlux 200W is a rigid panel that Renogy says uses “cell-level” anti-shading technology. The product page claims “up to 85% more output in partial shade” (checked Oct 26, 2026). Renogy doesn’t define the comparison panel or shade pattern behind that number on the page, and we haven’t tested it. Renogy itself recommends keeping more than half the panel in direct sun.
What the published specs mean for power stations (our math):
- Specs (Renogy page, Oct 26, 2026): 200 W, 36.5 V open-circuit, 6.86 A short-circuit, 31.3 V / 6.38 A working point, 23.83 lb, MC4 leads. $239.99 for one ($1.20/W) or $911.99 for four ($1.14/W), vs $1.90/W for one SolarSaga 200W at $379.
- One per input on 60 V stations, or two in parallel. Not two in series. Renogy doesn’t list a voltage temperature coefficient on the page; assuming −0.30%/°C, open-circuit voltage is about 41 V at −4°F, so two in series (~83 V) is over a 60 V input.
- Two in parallel is about 12.8 A working current and 13.7 A short-circuit. That’s within the DELTA 3 Plus’s 15 A rule (about 400 W), slightly over a Jackery 2000 Plus input’s 12 A (about 376 W), and well over the AC180’s 10 A (about 313 W).
- On high-voltage inputs: three in series is about 124 V at −4°F, inside the DELTA Pro 3 High-PV (150 V) and F3800 Plus (165 V) windows. Four in series is about 146 V at 77°F but about 166 V at −4°F on our assumed coefficient, which is over the F3800 Plus’s 165 V. Stop at three in cold climates.
- The catch: it’s a third-party panel. You’ll need an MC4 adapter for most stations, and some brands’ warranties exclude third-party accessories. See brand vs third-party solar panels and portable vs rigid panels.
A shade checklist for outage days
- Watch the panels for an hour on a sunny day before you need them. Note where shadows land at 9 AM, noon, and 3 PM, and re-check in winter, when noon shadows in the north are several times longer than in June.
- Keep every panel fully in sun. A shadow across one end can cost a third or more of the output.
- Group panels by spot: same shade, same input. Don’t mix a shaded panel and a sunny one in one series string.
- Edge shadow you can’t avoid? Series pairs held up better in our model. Whole panel in shade? Parallel or a separate input held up better.
- Keep the station itself in the shade, not the panels. EcoFlow sells 3 m extension cables so the station can sit “in the shade while the solar panels receive direct sunlight.” Longer cables cost some power, least when panels are wired in series (extension cable voltage drop).
- Clear leaves, snow, and droppings. EcoFlow lists “foreign objects” among the causes of “greatly reduce[d] power output.”
- Check the station’s solar input reading after you move panels. If it drops sharply when a shadow touches one panel, move that panel or put it on its own input.
To estimate what your setup can recharge per day, see how many solar panels to recharge a power station, then check your loads in the runtime calculator.
Bottom line
Shade costs far more power than its size suggests, because bypass diodes drop a whole group of cells at once. Placement comes first: leave room for winter shadows (5.5× an obstacle’s height at 9 AM in Minneapolis in late December). Wiring comes second: in our model, series held up better against edge shadows, parallel held up better when a whole panel was shaded, and separate inputs held up well in both cases. Group panels by where they sit, and give each group its own input.
Sources
- NREL (now NLR), C. Deline, Partially Shaded Operation of a Grid-Tied PV System (NREL/CP-520-46001, 2009): bypass diodes across 12–18 cells; half-cell shading example (checked Oct 26, 2026)
- Jackery, SolarSaga 200W (22 V Voc, 12.5 A Isc, 18 V / 11.5 A; −(0.27±0.03)%/°C; FAQ “no shadow”; $379, list $429), SolarSaga 200 (JS-200D) user guide (shaded-area warning), Explorer 2000 Plus (2 DC inputs: 11–17.5 V 8 A; 17.5–60 V 12 A; 24 A / 1,400 W), SolarSaga 500X (“each panel works independently”; parallel) (checked Oct 26, 2026)
- EcoFlow, 400W Solar Panel user manual (panel shading), 400W Portable Solar Panel page (3 m extension cable “in the shade” note), DELTA 3 Plus (“500W MPPT × 2”), DELTA Pro 3 (High-PV 30–150 V, 15 A, 1,600 W; Low-PV 11–60 V, 20 A, 1,000 W) (checked Oct 26, 2026)
- Anker SOLIX, PS200 and PS400 FAQs (rated-power answer), F3800 Plus (“dual MPPT,” “2 × 165VDC MPPT Input”) (checked Oct 26, 2026); F3800 Plus design guide (one array per MPPT input; checked Oct 24, 2026)
- BLUETTI, SP200L 200W Solar Panel FAQ (shading as a factor), AC180 (12–60 V, 10 A) (checked Oct 26, 2026)
- Renogy, ShadowFlux 120W/200W N-Type Anti-Shading Solar Panel (200 W: 36.5 V Voc, 6.86 A Isc, 31.3 V / 6.38 A, 23.83 lb; “up to 85% more output in partial shade”; “over half of the panel surface” advice; $239.99 single, $470.99 2-pack, $911.99 4-pack) (checked Oct 26, 2026). Voltage temperature coefficient not listed; −0.30%/°C is our assumption.
- Sun position: standard solar-geometry equations (declination by Cooper’s formula, solar time, no refraction), as used in NOAA’s Solar Calculator.
- StormWatts model:
research/sources-2026-10-26/shade-math.py(single-diode panel fit to published ratings at 77°F cells, ideal bypass diodes, 2 or 3 diode groups per panel, global maximum power point assumed).