Do Solar Panels Charge a Power Station on Cloudy Days? What You Really Get, City by City

How much a portable solar panel makes on an overcast day (about 5-30% of a clear day), how often that happens in 6 US cities, and how to size for it.

Short answer: yes, but a heavy overcast day gives you a small fraction of a sunny one. In our NLR (formerly NREL) PVWatts runs for six US cities, a heavily overcast day put about 5–30% of a clear day’s light on a panel, with a typical overcast day at 14–21%. For one 200 W panel that’s roughly 60–360 Wh into the battery instead of 800–1,400 Wh.

  • How often it happens depends a lot on where you live. In a typical weather year, about 1% of days in Phoenix, 6% in Denver, 15% in Minneapolis and Atlanta, 18% in Chicago, and 24% in Seattle were heavy overcast by our definition (below 30% of that month’s clear-day benchmark).
  • December is the hard month in the North. A typical overcast December day in Minneapolis or Chicago gave only about 0.36 sun hours. Putting 1 kWh a day into a battery on days like that would take about 3,200 W of panels, far more than any portable kit. On a median December day, about 410 W (Minneapolis) to 510 W (Chicago) does it.
  • Three gray days in a row are the real test. Our worst three-day winter stretch gave 400 W of panels only about 315–355 Wh in total in Minneapolis, Chicago, and Seattle, about a third of a 1 kWh station. In Denver it was about 1,600 Wh, and in Phoenix about 3,000 Wh.
  • On overcast days, light comes from the whole sky. Aiming matters less, and a flatter panel sees more of the sky. Under a simple sky model, a panel at 35° sees 91% of the sky; at 60° it sees 75% (our math).
  • Plan the battery for the gray days and the panels for the normal ones. Size panels for a median day in your worst month, and carry enough battery to cover a two- to three-day overcast stretch at reduced loads.

Safety first. Keep every panel string under the station’s maximum input voltage at your coldest temperature (series vs parallel guide). Don’t leave folding panels out in high wind or a storm. Never backfeed a house through a wall outlet; hardwired circuits need a transfer switch or inlet installed by a licensed electrician (transfer switch guide).

We haven’t measured cloudy-day output ourselves. The energy figures below come from NLR’s PVWatts V8 calculator with typical-year weather data and our own inputs (listed at the bottom). Panel prices come from each brand’s official US store, checked Oct 29, 2026. The StormWatts owner is running their own sunny-day readings with a Jackery Explorer 2000 Plus and four SolarSaga 200 panels; the first full sunny day is in our owner-tested solar article (696 W peak from 800 W of panels in late October). When the owner reports cloudy-day numbers, we’ll add them here and label them as owner-reported.

How we measured “cloudy” (model, not measurement)

PVWatts uses NSRDB typical meteorological year weather: a composite of real months picked to represent normal conditions at each place. It isn’t a forecast, and a real year can be cloudier.

For each city we ran a south-facing panel at a 35° tilt (a common kickstand angle) and summed the hourly light hitting the panel into daily sun hours (kWh per m² per day on the panel). Then, for each calendar month:

Clear-day benchmark = the 90th-percentile day of that month
  • Sunny: 70% or more of the benchmark.
  • Partly cloudy: 30–70%.
  • Heavy overcast: under 30%.

Energy into the battery uses our site-wide, labeled assumption:

Wh into battery ≈ panel watts × sun hours × 0.85

The 0.85 is our rough allowance for panel heat, wiring, and charge-controller losses. It’s the same assumption used in our solar panel count guide.

How often it’s heavily overcast, and what you get

CityHeavy overcast days per yearTypical overcast day vs clearRange on overcast daysDiffuse share on overcast days*
Phoenix3 (1%)14%14–24%53%
Denver23 (6%)21%6–29%83%
Atlanta54 (15%)17%6–29%88%
Minneapolis55 (15%)18%5–30%83%
Chicago66 (18%)14%4–30%91%
Seattle89 (24%)14%3–30%83%

* A rough index from PVWatts’ hourly weather: daily diffuse sky light ÷ (diffuse + direct beam). On sunny days it was 12–17% in every city. The point is the swing: on gray days nearly all the light is scattered sky light, not a beam from the sun.

Phoenix’s three overcast days are too few to say much about. Everywhere else, the typical heavily overcast day landed around one-seventh to one-fifth of a clear day.

December, the month that decides northern setups

What one 200 W panel would put into a battery in December (our math from the PVWatts runs):

CityClear December dayMedian December dayTypical overcast December dayWorst December day
Seattle528 Wh209 Wh70 Wh15 Wh
Minneapolis814 Wh489 Wh61 Wh43 Wh
Chicago852 Wh392 Wh62 Wh36 Wh
Denver1,005 Wh805 Wh140 Wh79 Wh
Atlanta1,084 Wh757 Wh186 Wh97 Wh
Phoenix1,113 Wh1,059 Wh210 Wh158 Wh

Minneapolis December clear days look strong partly because PVWatts’ weather file includes snow cover, which reflects extra light onto a tilted panel. Seattle stands out the other way: in its typical year, 14 of 31 December days and 16 of 31 January days were heavy overcast.

Panel watts to put 1 kWh a day into the battery in December

CityOn a clear dayOn a median dayOn a typical overcast day
Phoenix180 W189 W952 W
Atlanta184 W264 W1,075 W
Denver199 W248 W1,428 W
Chicago235 W510 W3,207 W
Minneapolis246 W409 W3,285 W
Seattle379 W959 W2,840 W

The overcast column is the reason “just add more panels” stops working in a northern winter. Three thousand watts of folding panels is fifteen 200 W panels, and most portable stations can’t accept that much solar anyway. Our solar compatibility guide lists each station’s input limit.

Three gray days in a row

We searched November through February for the worst three consecutive days in each city’s typical year, then multiplied by 400 W of panels:

CitySun hours over the 3 days400 W of panels, total into battery
Minneapolis0.93~315 Wh
Chicago0.94~321 Wh
Seattle1.04~355 Wh
Atlanta2.38~809 Wh
Denver4.75~1,614 Wh
Phoenix8.98~3,052 Wh

In the three northern cities, that’s about 100–120 Wh a day. It’s enough to keep phones, a router, and LED lights going on a modest budget, but not a refrigerator (about 1–2 kWh a day; see our refrigerator guide). For loads like that, the battery carries you through the gray stretch, and the panels catch up when the sun comes back.

What actually helps on cloudy days

  • Don’t chase the sun’s direction under a full overcast. With nearly all the light coming from the sky dome, pointing exactly at the hidden sun gains little. A flatter tilt sees more sky: by the simple isotropic-sky formula (1 + cos tilt) ÷ 2, a panel sees 100% of the sky flat, 91% at 35°, 82% at 50°, and 75% at 60°. On a bright day with low winter sun, the steeper angle still wins, as our winter solar guide shows. If the sky is solid gray all day, laying panels flatter is a reasonable tweak. On sunny days it’s the opposite: following the sun adds about 30–65% in our re-aiming guide, while on heavy overcast days it added only about 0–20%.
  • Mind the station’s low-voltage limits. Low light mostly cuts a panel’s current, but its voltage sags too, especially in parallel wiring at one panel’s voltage. Some stations change their current limit below a set voltage (Jackery’s Explorer 2000 Plus at 17.5 V, Anker’s C1000 Gen 2 at 28 V). Wiring two panels in series keeps the voltage well above those thresholds. Details are in our series vs parallel guide.
  • Watch for partial shade, not just clouds. A shadow across one panel can cost more than a thin overcast. See partial shade on portable panels.
  • Keep the panels clean and clear of snow. Snow on the face blocks light almost completely; snow on the ground in front can help a bit (bifacial guide).
  • Cut loads early. If the forecast shows several gray days, run the fridge on a schedule and drop nonessential loads on day one. The runtime calculator shows how long your loads last on battery alone.

Sizing for cloudy weather: a simple rule

  1. Panels: size for a median day in your worst month, not a clear day. For 1 kWh a day in December, that’s about 250 W in Denver or Atlanta, 400–500 W in Minneapolis or Chicago, and nearly 1,000 W in Seattle (table above).
  2. Battery: cover your essential loads for two to three days with little solar. For a 1 kWh-a-day essentials list in the North, that means 2–3 kWh of usable capacity, or a smaller daily budget. Our sizing guide walks through it.
  3. Backup to the backup: in long northern winter outages, a plan for wall or car charging, or a generator used safely outdoors, still matters (power station vs gas generator).

Brand-matched 200 W-class panels for the stations we track, on each brand’s official store on October 29, 2026:

Prices change often. Check which panel fits your station, and how many, in our best solar panels for each power station guide.

We apply these December numbers to a specific three-day load list in our 3-day outage plan with solar.

What this model doesn’t capture

  • Real years vary. A typical-year file smooths out the worst storms. A week-long winter gray spell can and does happen.
  • Your panel isn’t a 1 kW rooftop array. We scaled PVWatts’ light-on-panel numbers to a 200 W panel with our 0.85 factor. Folding panels on kickstands can do worse (wind tilt, dirt, partial shade) or better (cold cells in winter sun).
  • Station minimums aren’t modeled. Some stations may stop charging below a minimum input power or voltage. Brands don’t publish a minimum wattage for most models, so we couldn’t include it.
  • Six cities only. For your exact location, run PVWatts yourself with your tilt, or use the city tables in our winter and hurricane-season solar guides.

Sources

  • NLR (formerly NREL), PVWatts V8 API documentation and PVWatts V8 hourly runs via developer.nlr.gov with NSRDB typical-year weather for Minneapolis, Seattle, Chicago, Atlanta, Denver, and Phoenix (1 kW, standard module, fixed open rack, south-facing, 35° tilt, 14% losses; hourly plane-of-array irradiance, direct normal, and diffuse outputs) (run Oct 29, 2026)
  • Jackery, SolarSaga 200W ($379, list $429) (checked Oct 29, 2026); Explorer 2000 Plus solar input bands (11–17.5 V 8 A; 17.5–60 V 12 A; checked Oct 24, 2026, as recorded in our series vs parallel guide)
  • EcoFlow, NextGen 220W Bifacial Portable Solar Panel ($399; 2-pack $769) (checked Oct 29, 2026)
  • BLUETTI, 200W Portable Solar Panel (SP200L) ($349, list $399; 2 for $798) (checked Oct 29, 2026)
  • Anker SOLIX, PS200 Bifacial ($499.99) and C1000 Gen 2 (11–28 V 8.2 A; 28–60 V 14.5 A; 600 W max, from our spec dataset) (prices checked Oct 29, 2026)
  • StormWatts model: research/sources-2026-10-29/cloudy-math.py (day classification, December tables, three-day winter lows, sky view factor).