Short answer: solar still works in a northern winter, but you get roughly a third to half of June’s sun, and how you angle the panel matters more than anything else you control. Using NREL’s PVWatts model (now run by NLR, the National Laboratory of the Rockies) with its typical-year weather data for Minneapolis (queried Oct 23, 2026):
- An average December day gives about 2.9 peak sun hours on a panel tilted 60° toward the south, but only 2.1 hours at a shallow 20°. That’s 36% more energy just from propping the panel up steeper. In June, the shallow panel wins (6.2 vs 4.4 hours).
- Four 200 W panels (800 W) on a 2 kWh station refill roughly 96% of it on an average December day at 60°, and about 71% at 20° (our math: rated watts × sun hours × 85%). In Duluth or Buffalo, the same setup gets about 69–79% at 60°.
- The station must be above freezing to charge. Every station we checked (Jackery, EcoFlow, Anker SOLIX, BLUETTI) lists a charging range starting at 32°F. Keep it indoors and run the panel cable in.
- Cold raises panel voltage. That’s the same morning you’re most likely to need solar. Jackery, EcoFlow, and Anker all told us by email on Oct 22, 2026 to plan series strings for cold weather (details below).
These are averages from a “typical year.” A stormy week can be far worse than the average, so treat these numbers as what a clear-panel, typical December looks like, not a guarantee.
Safety first. Exceeding a power station’s input voltage can damage it. Use the limits in your unit’s manual and keep cold-weather margin. Never backfeed a house through a wall outlet; hardwired loads need a transfer switch or inlet installed by a licensed electrician (transfer switch guide). Don’t climb on icy roofs to clear panels. This page is research, not electrical advice.
We haven’t tested any panels for this article. The sun-hour figures come from NLR’s PVWatts V8 model, the station and panel specs from each brand’s official pages (checked Oct 23, 2026 unless noted), and the refill numbers are our math. The StormWatts owner uses a Jackery Explorer 2000 Plus with four SolarSaga 200 panels in a Minneapolis suburb in Minnesota, and nothing in the model figures here comes from that setup. The owner’s real late-October readings are in our owner-tested full day of solar: standing the panels nearly vertical at 3 PM raised input from 481 W to 636 W.
What “peak sun hours” means
A peak sun hour is 1 kWh of sunlight per square meter reaching the panel, the amount a panel’s watt rating is based on. If a south-facing panel gets 2.9 peak sun hours in a day, a 200 W panel would make about 200 W × 2.9 = 580 Wh before losses. We subtract 15% for wiring, charge-controller, and battery losses, the same 85% charge-path assumption used in our panel-count guide:
PVWatts reports sun hours on the tilted panel (its “plane-of-array” radiation), so the tilt and direction are already included. We ran each city with a fixed, south-facing (180°) open-rack array, standard modules, and PVWatts’ default 14% system losses. Those losses only affect PVWatts’ kWh estimates, not the sun-hour numbers we use. The weather data is NSRDB’s 2020 typical meteorological year (TMY).
December sun hours by city (south-facing panel)
PVWatts V8 plane-of-array radiation, kWh/m²/day (= peak sun hours), from NLR’s API (queried Oct 23, 2026):
| City | Dec, 20° tilt | Dec, 45° | Dec, 60° | Jan, 60° | Jun, 20° | Dec gain, 60° vs 20° |
|---|---|---|---|---|---|---|
| Minneapolis, MN | 2.13 | 2.75 | 2.89 | 3.87 | 6.15 | +36% |
| Duluth, MN | 1.79 | 2.26 | 2.36 | 2.93 | 6.06 | +32% |
| Fargo, ND | 1.97 | 2.54 | 2.66 | 3.20 | 6.35 | +35% |
| Madison, WI | 2.46 | 3.13 | 3.28 | 3.60 | 6.39 | +34% |
| Chicago, IL | 2.15 | 2.70 | 2.80 | 3.12 | 6.26 | +30% |
| Detroit, MI | 1.94 | 2.40 | 2.48 | 3.12 | 6.31 | +28% |
| Buffalo, NY | 1.62 | 1.99 | 2.06 | 2.66 | 6.14 | +27% |
| Denver, CO | 3.68 | 4.71 | 4.91 | 4.95 | 7.19 | +33% |
| Austin, TX (for comparison) | 3.93 | 4.60 | 4.62 | 4.62 | 6.42 | +18% |
How to read it:
- December is the worst month everywhere on the list. January is noticeably better in the Upper Midwest (Minneapolis 3.87 vs 2.89 at 60°).
- Cloud cover matters as much as latitude. Buffalo is farther south than Minneapolis but gets less December sun in this data. Denver, a little south of Chicago, gets about 75% more than Chicago.
- Steep tilt helps most in the north. At 20°, the panel faces too high for the low winter sun. In Austin the gain is smaller because the sun sits higher.
Best tilt by month (Minneapolis)
We ran the same Minneapolis location at five tilts. Peak sun hours per day, south-facing:
| Month | 20° | 30° | 45° | 60° | 90° (vertical) | Best of these |
|---|---|---|---|---|---|---|
| Jan | 2.83 | 3.24 | 3.66 | 3.87 | 3.98 | 90° |
| Feb | 3.77 | 4.20 | 4.63 | 4.83 | 4.78 | 60° |
| Mar | 5.13 | 5.43 | 5.61 | 5.49 | 4.66 | 45° |
| Apr | 5.37 | 5.40 | 5.21 | 4.75 | 3.50 | 30° |
| May | 5.56 | 5.37 | 4.87 | 4.12 | 2.47 | 20° |
| Jun | 6.15 | 5.89 | 5.26 | 4.38 | 2.49 | 20° |
| Jul | 6.78 | 6.55 | 5.89 | 4.96 | 2.82 | 20° |
| Aug | 5.85 | 5.82 | 5.49 | 4.85 | 3.15 | 20° |
| Sep | 5.12 | 5.29 | 5.28 | 4.96 | 3.73 | 30° |
| Oct | 3.57 | 3.83 | 4.03 | 3.99 | 3.45 | 45° |
| Nov | 2.61 | 2.92 | 3.21 | 3.31 | 3.17 | 60° |
| Dec | 2.13 | 2.44 | 2.75 | 2.89 | 3.01 | 90° |
What this means for a portable panel you can re-aim:
- November through February: go steep, about 60°. In December and January, PVWatts even puts a vertical panel slightly ahead. PVWatts’ weather data includes ground reflectance, which is higher when there’s snow on the ground, and that’s likely part of the reason. A vertical panel also sheds snow, but it catches more wind, so only do it if it’s secured.
- March and October: about 45°. April and September: about 30°. May through August: about 20°.
- A fixed 35° stand is a summer-leaning compromise up north. Anker says the PS400’s fixed 35° angle is calculated to optimize output “from 10 AM to 5 PM in Japan, the U.S., and Europe,” and that its bracket “allows slight adjustments” (PS400 FAQ). In a Minneapolis December, 35° sits between our 30° (2.44 hours) and 45° (2.75 hours) results, below the 2.89 hours at 60°. Shimming the panel steeper in winter is worth trying if it stays stable.
- Jackery’s SolarSaga 200W has “adjustable stands” and a “SolarTarget” aid to help you “manually angle your panel for maximum sun exposure” (SolarSaga 200W).
What a December day refills, by station
Minneapolis, average December day, rated panel watts × sun hours × 0.85 (our math). Capacities and solar limits are from each brand’s product page (checked Oct 23, 2026). Panel layouts are the cold-safe ones from our best solar panels for each power station guide.
| Station (capacity) | Example array | Wh/day at 60° tilt | Share of battery | Wh/day at 20° | Share |
|---|---|---|---|---|---|
| Jackery Explorer 2000 Plus (2,042.8 Wh) | 4 × SolarSaga 200W, 2 in series per input (800 W) | ≈ 1,960 | ≈ 96% | ≈ 1,450 | ≈ 71% |
| EcoFlow DELTA 3 Plus (1,024 Wh) | 2 × EcoFlow 400W, one per input (800 W) | ≈ 1,960 | full | ≈ 1,450 | full |
| EcoFlow DELTA Pro 3 (4,096 Wh) | 4 × EcoFlow 400W: 2 in series on High-PV + 2 in parallel on Low-PV (1,600 W) | ≈ 3,920 | ≈ 96% | ≈ 2,890 | ≈ 71% |
| Anker SOLIX F3800 Plus (3,840 Wh) | 8 × PS400, 2 in series × 2 in parallel per input (3,200 W) | ≈ 7,850 | full | ≈ 5,790 | full |
| BLUETTI AC180 (1,152 Wh) | 2 × BLUETTI 200W (SP200L), in series (400 W) | ≈ 980 | ≈ 85% | ≈ 720 | ≈ 63% |
| Anker SOLIX C1000 Gen 2 (1,024 Wh) | 2 × ~22–25 V 200 W panels in series (400 W) | ≈ 980 | ≈ 96% | ≈ 720 | ≈ 71% |
“Full” means the array could make more than the battery holds on an average December day. That surplus is useful if you’re running loads at the same time.
Panel watts needed to refill a 2,042.8 Wh Explorer 2000 Plus in one average December day (our math, 60° tilt / 20° tilt): Minneapolis about 830 W / 1,130 W, Duluth 1,020 / 1,340 W, Fargo 900 / 1,220 W, Madison 730 / 980 W, Chicago 860 / 1,120 W, Detroit 970 / 1,240 W, Buffalo 1,160 / 1,480 W, Denver 490 / 650 W, Austin 520 / 610 W. The 2000 Plus accepts up to 1,400 W of solar (two 12 A inputs, per Jackery’s product page), so a full one-day December refill is possible on paper in most of these cities with the right panels. With SolarSaga 200W panels, we’d stay at four panels (800 W, two in series per input) until Jackery clarifies how its six-panel adapter setup is wired (see best solar panels for each power station).
For outage planning, it helps to flip the question: how many watt-hours a day can your loads use if the sun is all you have? In Minneapolis in December, 800 W of panels at 60° averages about 1.9 kWh a day into the battery. Enough for a refrigerator and a gas furnace blower on a mild day? Check with the runtime calculator.
Cold mornings: panel voltage goes up
Panel voltage rises as cells get colder, and open-circuit voltage (Voc) peaks on cold, sunny mornings before the station starts drawing current. Our formula, the same one used in our compatibility guide (and in our series vs parallel guide, which covers when splitting panels into parallel avoids the cold-voltage problem):
| Setup | Station limit | 77°F | −4°F | −22°F | −22°F with +5% Voc tolerance |
|---|---|---|---|---|---|
| 2 × Jackery SolarSaga 200W (22 V ±5%, −(0.27±0.03)%/°C) | 60 V | 44.0 V | 49.3 V | 50.5 V | 53.1 V |
| 2 × SolarSaga 200, older JS-200D (24.8 V, −0.268%/°C) | 60 V | 49.6 V | 55.6 V | 56.9 V | 59.8 V |
| 2 × BLUETTI 200W SP200L (24.6 V; coefficient not listed, we assume −0.33%/°C) | 60 V | 49.2 V | 56.5 V | 58.1 V | 61.0 V |
| 1 × EcoFlow 400W (48 V, −0.33%/°C) | 60 V | 48.0 V | 55.1 V | 56.7 V | 59.5 V |
| 2 × EcoFlow 400W on DELTA Pro 3 High-PV | 150 V | 96.0 V | 110.3 V | 113.4 V | 119.1 V |
| 3 × EcoFlow 400W on DELTA Pro 3 High-PV | 150 V | 144.0 V | 165.4 V | 170.1 V | 178.6 V |
Specs: SolarSaga 200W and SP200L from their product pages (checked Oct 23, 2026); JS-200D from its user guide and the EcoFlow 400W from its user manual (checked Oct 20, 2026). At dawn, before the panel warms up, its temperature is roughly the air temperature.
- The +5% column is a worst case, not a prediction. Brands list Voc with a tolerance (Jackery prints ±5%), and most panels land near the nominal value. Still, the older JS-200D pair and the BLUETTI pair have very little margin on a 60 V input on a very cold morning. Read the label on your own panels and use your coldest sunny morning.
- Panel ratings have cold limits too. Jackery lists the SolarSaga 200W’s operating range as −4°F to 149°F; BLUETTI lists the SP200L at −13°F to 149°F. Below that, you’re outside the published rating.
What the brands told StormWatts by email (Oct 22, 2026):
- Jackery support: “Please do not connect three SolarSaga 200W panels in series to one DC input port” on the Explorer 2000 Plus, because the string exceeds the 60 V limit, which “may prevent charging or cause product damage.” Jackery also said both inputs must use the same panel model and count, with up to six panels total.
- EcoFlow support (case CAS-20261022-2098456): the DELTA Pro 3 manual’s three-in-series diagram “is an example based on standard electrical parameters and does not apply to all climate conditions.” Series Voc “should be recalculated according to the minimum expected local temperature,” and for cold climates with three 400W panels EcoFlow recommends two in series on High-PV and the third on Low-PV.
- Anker SOLIX support (ticket ANKER-TNX8721417221): Anker “does not publish a specific temperature coefficient for the PS200” and recommends monitoring Voc in sub-freezing weather and staying under the C1000 Gen 2’s 60 V limit. On the F3800 Plus with 440W rigid panels, “it is safer to use three panels in series per input port, especially in sub-freezing conditions.”
These are customer-support answers, not published documentation. They’re consistent with the math above.
The 32°F charging rule
Cold panels are fine. Cold batteries are the problem. Each brand lists a charging temperature range on its product page (checked Oct 23, 2026):
| Station | Charging temperature | Discharging temperature |
|---|---|---|
| Jackery Explorer 2000 Plus, Explorer 1000 v2, Explorer 2000 v2 | 32–113°F (0–45°C) | 14–113°F (−10–45°C) |
| EcoFlow DELTA Pro 3 | 32–113°F (0–45°C) | 14–113°F (−10–45°C) |
| Anker SOLIX C1000 Gen 2, F3800 Plus | 32–104°F (0–40°C) | −4–104°F (−20–40°C) |
| BLUETTI AC180 | 32–104°F (0–40°C) | −4–104°F (−20–40°C) |
So in a Minnesota winter, the panels go outside and the station stays inside, somewhere above freezing. An unheated garage or porch can drop below 32°F. Run the panel’s cable in through a door or window gap without pinching it, and use the brand’s extension cable if you need more length rather than splicing your own. Jackery also sells an “Extreme Guard” carrying bag for the Explorer 2000 v2 with a heating module rated to operate from −4°F (Explorer 2000 v2 page); we haven’t used it.
Snow, shade, and short days
- Snow on the panel blocks almost everything. PVWatts’ sun-hour figures assume a clear panel. A portable panel is easy to fix: bring it in during the storm, set it out after, or brush it off with something soft. Jackery says the SolarSaga 200W is IP68 and “performs reliably in rain, snow, dust, sand, and dirt” (SolarSaga 200W). Folding panels are light, so stake or weight them against wind. For what each brand’s IP rating does and doesn’t cover (and why the plugs and the station are the weak spots), see can portable solar panels stay out in rain and snow?
- Snow on the ground can help. Bright snow reflects light onto the panel, and bifacial panels such as Anker’s PS400 (which Anker says gathers light from both sides “in reflective or open areas such as snow, sand, or concrete”) can use some of the light that reaches their back side. We don’t have brand data for how much that adds in winter.
- Winter shadows are long. On December 21 at solar noon, the sun is only about 21.6° high in Minneapolis (90° − latitude − 23.44°, our math), so anything casts a shadow about 2.5 times its height: a 6 ft fence shades about 15 ft of yard at noon, and more in the morning and afternoon. In Duluth and Fargo it’s about 2.8 times. Shade on one panel in a series string can drag down the whole string, so put the panels where nothing is south of them. Our partial shade guide has shadow lengths for four cities and the series vs parallel trade-offs in shade.
- Face true south, and re-aim if you can. The tables above assume a fixed south-facing panel. If you’re home during an outage, turning a portable panel to follow the sun helps. Our re-aiming guide models it: in December, a steep panel turned southeast, south, then southwest got about 22% more light in Minneapolis than a fixed 35° panel.
Bifacial panels get a small boost from snow on the ground: in our PVWatts runs, about +9–11% in a Minneapolis January and February at a 30° tilt, much less than steeper tilt adds. See bifacial panels: how much the back side adds.
A winter solar checklist
- Check your panels’ Voc label and your station’s input limit. Do the cold-morning math for your coldest sunny day (table above), and keep a margin.
- Tilt the panels about 60° from November to February, face them true south, and keep the area south of them clear of shade.
- Keep the station indoors above 32°F. Only the panels and cable go outside.
- Clear snow gently, from the ground, and store folding panels during storms.
- Plan loads around the December average for your city, and expect worse on cloudy days.
- Size the battery for the days with no sun at all: sizing guide or runtime calculator.
Choosing panels? See best solar panels for each power station, portable vs rigid panels, and brand vs third-party panels. For year-round panel counts, see how many solar panels to recharge a power station.
Live on the Gulf or Atlantic coast instead? See solar backup for hurricane-season outages for summer and fall sun hours and cloudy-day lows.
For how much a panel makes on a fully gray day, how often that happens in six cities, and the worst three-day winter stretches, see solar panels on cloudy days.
Sources
- NLR (formerly NREL), PVWatts V8 API (NSRDB PSM V3 2020 TMY weather; fixed open rack, 180° azimuth, standard module, 14% losses; tilts 20°, 45°, 60° for all cities and 30°, 90° for Minneapolis), queried Oct 23, 2026. Also available as the PVWatts Calculator.
- Jackery, Explorer 2000 Plus (2,042.8 Wh; charge 32–113°F), Explorer 1000 v2, Explorer 2000 v2 (incl. Extreme Guard bag heating module), SolarSaga 200W (22 V ±5% Voc, −(0.27±0.03)%/°C, 60 V max system voltage, −4°F to 149°F) (checked Oct 23, 2026); SolarSaga 200 User Guide (JS-200D) (checked Oct 20, 2026)
- EcoFlow, DELTA Pro 3 (4,096 Wh; High-PV 30–150 V; charge 32–113°F), DELTA 3 Plus (1,024 Wh) (checked Oct 23, 2026); 400W Solar Panel user manual (48 V Voc, −0.33%/°C) (checked Oct 20, 2026)
- Anker SOLIX, C1000 Gen 2 (1,024 Wh; charging 32–104°F), F3800 Plus (3,840 Wh; charging 32–104°F), PS400 Bifacial (35° fixed angle FAQ; bifacial) (checked Oct 23, 2026)
- BLUETTI, AC180 (1,152 Wh; charging 32–104°F), 200W Portable Solar Panel (SP200L) (24.6 V Voc; −13°F to 149°F) (checked Oct 23, 2026)
- Support emails to StormWatts, Oct 22, 2026: Jackery support; EcoFlow support (case CAS-20261022-2098456); Anker SOLIX support (ticket ANKER-TNX8721417221). Customer-support answers, not published documentation.
- Our math: refill = rated W × peak sun hours × 0.85; cold Voc formula above; noon sun altitude on Dec 21 = 90° − latitude − 23.44°.