Short answer: on the Gulf and Southeast Atlantic coasts, an average day from August through October gives a south-facing panel about 5.2 to 5.7 peak sun hours. That’s plenty. The trouble is the cloudy stretch: in the same months, the worst three days in a row in the typical-year weather data average only 1.6 to 3.0 peak sun hours. Size your battery for that cloudy stretch and your panels for the average day, and solar can carry a small essentials load through an outage that lasts a week or more.

  • Lights, router, phones and a ceiling fan (about 1.3 kWh a day from the battery, our estimate): roughly 300 W of panels covers an average day in every coastal city we checked. About 450 to 700 W covers a dim day (the 10th-percentile day).
  • Add a full-size fridge (about 3.9 kWh a day with our conservative fridge assumption): roughly 800 to 900 W of panels on an average day, and the battery also has to carry the fridge through each night, so a ~1 kWh station is too small. A 3.5–4 kWh station with 1,000–1,600 W of solar is the realistic floor.
  • Add a small window AC for 8 hours (about 6.4 kWh a day): you need 1,300+ W of panels on an average day and a lot more on cloudy ones. Only the biggest stations with big arrays keep up.

Safety first. Bring folding panels inside before high winds arrive, and set them back up only after the storm passes and the area is safe. Run power stations indoors; never run a gas generator indoors or in a garage (our generator comparison). Never backfeed a house through a wall outlet; hardwired loads need a transfer switch or inlet installed by a licensed electrician (transfer switch guide). If someone depends on powered medical equipment, plan with their provider. This page is research, not electrical or medical advice.

We haven’t tested any of this gear. Sun-hour figures come from NLR (formerly NREL) PVWatts, retrieved Oct 25, 2026. Station specs come from each brand’s official product page (checked Oct 22, 2026, in our power station dataset). Appliance loads are typical estimates from our runtime calculator dataset, and every load and efficiency number below is labeled as our assumption.

Why hurricane-season solar is a different problem

The Atlantic hurricane season runs June 1 to November 30, according to the National Hurricane Center (checked Oct 25, 2026). Long outages after a storm aren’t like a winter outage up north. The sun is high and the days are long, so the average day is generous. What hurts is heat (you want fans or AC, and food spoils faster) and the run of gray, rainy days that can sit around a storm.

So the question isn’t “can solar refill my station in a day?” (we covered that in how many panels to recharge a power station). It’s “can solar keep up with what I use every day, and can my battery ride out the cloudy days in between?”

Peak sun hours by city, June to November

One peak sun hour is one hour of sunlight at full rated intensity (1,000 W/m²). We pulled PVWatts V8 for each city with a south-facing panel tilted 25° on an open rack, using its typical-year weather file (NSRDB tmy-2020) and default 14% system losses. The numbers are the solar energy reaching the panel surface per day.

CityJunJulAugSepOctNovAug–Oct 10th-pct dayWorst 3 days in a row (Aug–Oct)
Houston, TX5.956.065.895.615.384.862.922.46
New Orleans, LA5.845.565.495.885.814.903.432.42
Mobile, AL5.935.675.535.865.654.723.042.98
Tampa, FL5.635.385.345.595.865.493.322.55
Miami, FL5.425.755.795.565.355.133.482.92
Charleston, SC6.136.035.625.505.234.702.802.24
Wilmington, NC6.025.965.585.104.954.582.211.61
Minneapolis, MN (for comparison)6.046.685.865.223.712.771.691.64

Source: NLR PVWatts V8 hourly output, retrieved Oct 25, 2026. Monthly columns are averages. The “10th-pct day” is the day that 90% of August–October days beat. “Worst 3 days” is the lowest three-day average in those months. Our processing; the script is listed under Sources.

Three things stand out:

  1. The average day is steady. August to October averages land between about 4.9 and 5.9 sun hours everywhere on the coast. That’s more than the “mid” 4.5-hour scenario we use elsewhere on the site.
  2. The cloudy tail is the real constraint. A 10th-percentile day delivers only about half of an average day, and a bad three-day run can drop to a third or less. Wilmington’s worst run (1.61) is no better than Minneapolis in the same months.
  3. Typical-year data isn’t storm data. PVWatts uses a “typical” year built from many years of weather, so it smooths out rare events. The days right around a landfall can be darker than anything in this table. Treat the “worst 3 days” column as a planning floor, not a guarantee.

How much you use per day (our estimates)

These loads use the typical wattages in our runtime calculator dataset (published ranges from Champion and Honda generator sizing charts) and our own duty-cycle assumptions. We divide by our standard 85% inverter efficiency to get what comes out of the battery.

Daily loadAC energyFrom the battery
Router (24 h), 4 LED bulbs (5 h), phone/laptop charging (3 h), 1 ceiling fan (8 h)1,140 Wh1,341 Wh
The above + full-size fridge (275 W, 33% duty, 24 h)3,318 Wh3,904 Wh
The above + 5,000 BTU window AC (525 W, 8 h at 50% duty)5,418 Wh6,374 Wh

The fridge line is deliberately conservative: our 33% duty assumption works out to about 2.2 kWh a day. Many newer fridges use less. The yellow EnergyGuide label tells you: kWh per year ÷ 365 is your fridge’s real daily use, and it’s worth swapping in. (Our fridge guide walks through it.)

Panel watts to keep up from the sun alone

Panel watts needed = battery Wh per day ÷ (peak sun hours × 0.85). The 0.85 is our labeled solar charge-path efficiency assumption, the same one the rest of the site uses.

CityEssentials, average dayEssentials, 10th-pct day+ Fridge, average day+ Fridge, 10th-pct day+ Fridge + window AC, average day
Houston280 W541 W816 W1,573 W1,333 W
New Orleans276 W460 W802 W1,339 W1,310 W
Mobile278 W519 W809 W1,510 W1,321 W
Tampa282 W475 W820 W1,383 W1,340 W
Miami283 W453 W825 W1,318 W1,347 W
Charleston290 W564 W843 W1,640 W1,376 W
Wilmington303 W714 W881 W2,079 W1,439 W

Our math from the PVWatts table and the loads above. Rounded. Panels are rated watts; real output is usually lower than the label, and the 85% factor only partly covers that.

In plain terms: two 200 W panels handle the essentials on most days, and about 800–900 W of panels (four or five 200 W panels) handle the essentials plus a fridge on an average day, but not on a cloudy one. That’s why the battery matters as much as the panels.

The battery has to cover the night

Solar only charges in the daytime. A fridge, router and fan keep running all night. As a rough planning rule (our assumption), about two thirds of an all-day load happens outside the strong-sun hours, so the battery has to hold about that much each evening:

  • Essentials: about 0.9 kWh overnight. A ~1 kWh station works, but with little margin.
  • Essentials + fridge: about 2.6 kWh overnight. That’s more than a 1 kWh station or even a ~2 kWh station holds, unless you add an expansion battery (expansion battery chart) or cut the fridge’s runtime.
  • With a window AC as well: about 4.2 kWh overnight, which is flagship territory.

Station by station: does it keep up in Houston?

Each station’s solar input has a watt cap, so past a point more panels add nothing (series vs parallel and input limits). Here’s an energy balance for Houston’s August–October average day (5.63 sun hours) and its worst three-day run (2.46). Daily harvest = array watts (up to the station’s cap) × sun hours × 0.85.

Station (official specs, checked Oct 22, 2026)BatterySolar input capExample arrayHarvest, average dayHarvest, worst runEssentials (1.34 kWh)+ Fridge (3.9 kWh)
EcoFlow DELTA 3 Plus1,024 Wh1,000 W (2 × 500 W)800 W (2 × EcoFlow 400W, one per input)3,826 Wh1,672 WhKeeps up, even on the worst daysBattery too small for the night
Jackery Explorer 2000 Plus (StormWatts owner’s model)2,042.8 Wh1,400 W (2 inputs)800 W (4 × SolarSaga 200W, 2 in series per input)3,826 Wh1,672 WhKeeps up, even on the worst daysAverage days nearly break even, but the battery is short for the night; add the Battery Pack 2000 Plus
Jackery HomePower 3600 Plus3,584 Wh1,000 W1,000 W4,782 Wh2,090 WhKeeps upKeeps up on average days; on the worst run it loses about 1.8 kWh a day, so about 2 days of buffer
EcoFlow DELTA Pro 34,096 Wh2,600 W1,600 W (4 × EcoFlow 400W, 2S High-PV + 2P Low-PV)7,652 Wh3,343 WhKeeps upKeeps up on average days; loses about 0.6 kWh a day on the worst run (about 7 days of buffer)
Anker SOLIX F3800 Plus3,840 Wh3,200 W (2 × 1,600 W)3,200 W (8 × PS400, 2S2P per input)15,303 Wh6,687 WhKeeps upKeeps up, even on the worst run; also covers the window AC line in Houston’s worst run (on paper)

Our math. “Keeps up” means the day’s harvest covers the day’s load; it still assumes the battery is big enough to carry the overnight share. The Jackery 1000 v2 and 2000 v2 (400 W solar cap) and BLUETTI AC180 (500 W) top out at about 1.9–2.4 kWh of harvest on an average Houston day, which covers essentials but not a fridge. Array wiring examples follow each brand’s published limits, explained in our best solar panels for each power station guide.

Swap in Wilmington’s worst run (1.61 sun hours) and the margins shrink. The DELTA Pro 3’s 1,600 W array then harvests about 2.2 kWh a day, so the fridge scenario loses about 1.7 kWh a day (roughly 2.4 days of buffer), and even the F3800 Plus with 3,200 W falls about 2 kWh a day short with the window AC running.

A simple plan for a hurricane-coast household

  1. Pick your must-run list. Add it up in the runtime calculator, using your fridge’s EnergyGuide number instead of our estimate.
  2. Size the battery for one night plus one cloudy day. For essentials plus a fridge, that’s roughly 4–6 kWh. Under that, plan to shut the fridge off overnight and keep the door closed.
  3. Size the panels for an average day: daily battery Wh ÷ (about 5.5 × 0.85). Then check that the array fits the station’s voltage and amp limits (compatibility guide).
  4. Charge everything to full when a storm is forecast. You start the outage with a full battery, which buys the first night and day.
  5. Store panels indoors through the storm, then set them up facing south, tilted roughly 20–30°, away from shade and debris.

Bottom line

Hurricane-coast sun is generous on an average day, so a few hundred watts of panels keep the basics alive indefinitely, and around 800–1,600 W can carry a fridge as well, if the battery can carry it overnight. The cloudy days are what decide it. Plan the battery around the worst stretch, plan the panels around the average day, and keep the AC as a bonus for sunny afternoons rather than a promise.

Outside hurricane season, see solar panels on cloudy days for how often heavy overcast hits six other US cities and what a 200 W panel makes on those days.

Sources