Short answer: EcoFlow’s new DELTA 3000 Gen4 (3,072 Wh) has one solar port rated 1,000 W, 11–60 V, 20 A max, and the DELTA 3800 Gen4 (3,763 Wh) has two of them (2,000 W total). That’s more solar per port than the DELTA 3 Plus (500 W per port) or the DELTA 3 Ultra it replaces. But the 60 V ceiling and 20 A limit mean a single port is hard to fill: by our arithmetic, two of EcoFlow’s own 220 W panels reach only 440 W, and two 400 W panels reach about 800 W, and only by using a parallel connection that sits right at the current limit. The practical answer for most people is “about 400–800 W per port,” which still refills the 3000 Gen4 in roughly 4.5–9 sun-hours.
- Not shipping yet. EcoFlow’s pages say the 3000 Gen4 ships in early December and the 3800 Gen4 in late November. We haven’t tested either one, and everything below is EcoFlow’s published specs plus our own math.
- New connector. The Gen4 solar port is called LP60, not the XT60 used on earlier DELTA models. The box includes an XT60i to LP60 cable; EcoFlow’s panels end in XT60-style plugs.
- No high-voltage input. The DELTA Pro 3 has a second, high-voltage solar input (30–150 V). The Gen4 models only list the 11–60 V window.
Safety first. Keep every panel string under the port’s maximum voltage even on your coldest morning (cold raises voltage), use only cables and panels the manufacturer says fit, and never backfeed a house through a wall outlet. Hardwired circuits need a transfer switch or inlet installed by a licensed electrician (transfer switch guide).
What EcoFlow publishes
| DELTA 3000 Gen4 | DELTA 3800 Gen4 | |
|---|---|---|
| Battery | 3,072 Wh LFP | 3,763 Wh LFP |
| AC output | 3,600 W (7,200 W surge) | 3,600 W (7,200 W surge) |
| Solar input | 1 port, 1,000 W, 11–60 V DC, 20 A max | 2 ports, 2,000 W total, 1,000 W each, 11–60 V DC, 20 A max |
| Solar port type | LP60 (cable in the box: XT60i to LP60) | LP60 |
| Weight | 57.3 lb (26 kg) | about 30.6 kg (EcoFlow’s FAQ) |
| Expansion | None listed | Extra Battery Port, up to 2 extra packs |
| AC wall input | 1,800 W | 1,800 W |
| Shipping per EcoFlow | “Early December” | “Late November” |
DELTA 3000 Gen4 and DELTA 3800 Gen4 product pages on EcoFlow’s US store, plus EcoFlow’s DELTA Gen4 spec page, checked Nov 5, 2026. Prices change often; confirm at checkout.
EcoFlow’s own FAQ on the same pages says the main upgrades over the DELTA 3 Ultra are weight and solar input: 800 W per channel before, 1,000 W per channel now.
The rule we used to see what fits
A solar port accepts power only while the panels’ voltage and current stay inside its window. The labeled window is 11–60 V and 20 A, so we used a simple version:
- Voltage: add up the panels’ open-circuit voltage (Voc) for everything wired in series, and keep it at or under 60 V even when cold. We used −4°F (−20°C) and a −0.33%/°C voltage coefficient (the one published for EcoFlow’s 400 W panel; the 220 W page lists none, so we assumed the same).
- Current: add up the panels’ short-circuit current (Isc) for everything wired in parallel, and keep it at or under 20 A.
- Power: a port is capped at 1,000 W no matter how big the array.
This is our reading of the published window. We couldn’t open EcoFlow’s Gen4 manual, so check the manual for the exact rule before you wire anything. For the closest published example, EcoFlow’s DELTA Pro 3 manual shows two 400 W panels in parallel (48 V, 19.6 A) on its own 11–60 V, 20 A input, which is why we mark that layout “at the limit” instead of “over.”
What fits on one port
Panel numbers come from EcoFlow’s pages and manual: the 400 W portable panel (Voc 48 V, Isc 11 A, Vmp 41 V, Imp 9.8 A) and the NextGen 220 W bifacial (Voc 21.5 V, Isc 12.4 A, Vmp 18.4 V, Imp 11.9 A, front side).
| Layout on one port | Panel watts | Cold Voc (−4°F) | Isc | Fit (our rule) |
|---|---|---|---|---|
| 1 × 400 W | 400 W | 55.1 V | 11 A | Fits |
| 2 × 400 W in parallel | 800 W | 55.1 V | 22 A (Imp 19.6 A) | At the limit: over 20 A on Isc, under on Imp |
| 2 × 400 W in series | 800 W | 110 V | 11 A | Over 60 V |
| 3 × 400 W in parallel | 1,200 W | 55.1 V | 33 A | Over 20 A |
| 1 × 220 W | 220 W | 24.7 V | 12.4 A | Fits |
| 2 × 220 W in series | 440 W | 49.4 V | 12.4 A | Fits |
| 2 × 220 W in parallel | 440 W | 24.7 V | 24.8 A | Over 20 A |
| 3 × 220 W in series | 660 W | 74.1 V | 12.4 A | Over 60 V |
| 2S2P of 220 W | 880 W | 49.4 V | 24.8 A | Over 20 A |
What this says in plain words:
- The 1,000 W label is a ceiling, not an array size. With EcoFlow’s own panels, 400–800 W per port is what our rule allows. The 3800 Gen4’s second port doubles that to about 800–1,600 W.
- Series wiring runs out of room fast. A 400 W panel is already 48 V, so you can’t put two in series on a 60 V port. This is the biggest practical difference from the DELTA Pro 3, whose high-voltage input is designed for three 400 W panels in series (best panels for each station).
- Parallel wiring runs into the 20 A limit. That’s why 220 W panels (12.4 A each) work in series but not in parallel here.
- Two sunny panels may be enough for the 3000 Gen4. At 800 W, the station refills from empty in about 4.5 sun-hours (below).
- Availability: EcoFlow’s store showed the 400 W portable panel as unavailable on Nov 5, and the 220 W bifacial at $449. The Gen4 page’s own solar bundle is two 160 W panels, which EcoFlow says charges “in ~12 hrs” with 320 W; that agrees with our math below (about 11 hours).
How long a refill takes
That’s the same formula and 0.85 assumption used across StormWatts (panel count guide). Days to refill from empty, if you get 3, 4.5, or 6 peak sun-hours a day:
| Array on the station | Sun-hours | At 3 / 4.5 / 6 sun-hours a day |
|---|---|---|
| 3000 Gen4, 2 × 160 W (320 W, EcoFlow’s bundle) | 11.3 | 3.8 / 2.5 / 1.9 days |
| 3000 Gen4, 2 × 220 W in series (440 W) | 8.2 | 2.7 / 1.8 / 1.4 days |
| 3000 Gen4, 2 × 400 W in parallel (800 W) | 4.5 | 1.5 / 1.0 / 0.8 days |
| 3000 Gen4 at the 1,000 W cap (on paper) | 3.6 | 1.2 / 0.8 / 0.6 days |
| 3800 Gen4, 2 × 400 W on each port (1,600 W, if both ports fit as above) | 2.8 | 0.9 / 0.6 / 0.5 days |
| 3800 Gen4 at the 2,000 W cap (on paper) | 2.2 | 0.7 / 0.5 / 0.4 days |
Real charging tapers near full and rarely hits panel ratings (why rated watts aren’t real watts), so treat these as planning numbers. For a winter storm, the useful comparison is a gray December day, which usually gives well under 3 effective sun-hours in northern cities (cloudy-day guide, 3-day outage plan).
What it costs right now
EcoFlow’s pages list a web-only early-bird price through December 7, 2026, plus a subscribe-for-5%-off offer (“prices from $1,234”) that EcoFlow says can’t be combined with other promotions, and a 60-day price-match on us.ecoflow.com orders.
| Model | Early-bird price | List price | Per kWh (early-bird / list, our math) |
|---|---|---|---|
| DELTA 3000 Gen4 | $1,299 | $1,699 | about $423 / $553 |
| DELTA 3800 Gen4 | $1,699 | $2,199 | about $452 / $584 |
| DELTA Pro 3 (for comparison) | $2,799 sale, standalone unit showed unavailable Nov 5 | $3,299 | about $683 / $805 |
The cheaper-per-kWh Gen4 comes with trade-offs the table doesn’t show: a solar input limited to 60 V, no listed expansion on the 3000, and no 240 V output listed on these pages. If you want high-voltage solar or 240 V, the DELTA Pro 3 is still the model with those features; our flagship comparison covers the rest, and the cost per kWh table tracks weekly prices for eight models (the Gen4 isn’t in that dataset yet, since it hasn’t shipped).
Who should care
- You already own EcoFlow panels (XT60 plugs) and want a bigger battery: you need the XT60i-to-LP60 cable (included in the box), and you’ll land at 400–800 W per port.
- You’re shopping for the most solar on one port: a single large-format panel or two 400 W panels in parallel is the realistic route; a long series string (the DELTA Pro 3 approach) is out.
- You want to wait: neither model is shipping yet, and EcoFlow says the early-bird price has a 60-day price protection. We’ll update this page once they ship and the Gen4 manual is public.
Products mentioned
- EcoFlow DELTA 3000 Gen4 and DELTA 3800 Gen4
- EcoFlow DELTA Pro 3
- EcoFlow 400W Portable Solar Panel and NextGen 220W Bifacial Panel
Related guides
- Series vs parallel wiring, MPPT current bands, and overpaneling
- Best solar panels for each power station
- Solar panel compatibility for power stations
- Expansion battery compatibility
- Jackery HomePower 2000 Plus v2 vs Explorer 2000 Plus: solar input compared
Sources
- EcoFlow US, DELTA 3000 Gen4 (3,072 Wh; 3,600 W / 7,200 W; Max PV input 1,000 W, 1 port, 11–60 V DC, 20 A max; 57.3 lb; XT60i-to-LP60 cable in the box; $1,699 list / $1,299 web-only early-bird; “ships in early December”; early-bird, 5%-subscribe, trolley, and 60-day price-match terms; FAQ on 800 W vs 1,000 W per channel) (checked Nov 5, 2026)
- EcoFlow US, DELTA 3800 Gen4 (3,763 Wh; 2,000 W total, 2 ports, 11–60 V DC, 20 A max, 1,000 W each; Extra Battery Port; $2,199 list / $1,699 early-bird; “ships in late November”) and DELTA Gen4 series specs (checked Nov 5, 2026)
- EcoFlow US, NextGen 220W Bifacial Portable Solar Panel (Voc 21.5 V, Vmp 18.4 V, Isc 12.4 A, Imp 11.9 A front; $449) and 400W Portable Solar Panel (shown unavailable) (checked Nov 5, 2026)
- EcoFlow 400W Portable Solar Panel manual (Voc 48 V, Vmp 41 V, Isc 11 A, Imp 9.8 A; voltage coefficient −(0.33±0.03)%/K) and EcoFlow DELTA Pro 3 user manual (High-PV 30–150 V 15 A; Low-PV 11–60 V 20 A; 2 × 400 W parallel example 48 V / 19.6 A) (checked Oct 20, 2026)
- EcoFlow US, DELTA Pro 3 ($2,799 sale, $3,299 list; standalone unit showed unavailable on EcoFlow’s product feed) (checked Nov 5, 2026)
- StormWatts math:
research/sources-2026-11-05/gen4-solar-math.py(+gen4-solar-math.out.txt); 0.85 solar charge-path efficiency and the voltage/current rule are our assumptions, labeled above