Short answer: On paper, the Jackery Explorer 5000 Plus takes the most solar (5,200 W across its High-PV and Low-PV ports), then the Anker SOLIX F3800 Plus (3,200 W), the new Anker SOLIX S5000 (3,000 W), and the EcoFlow DELTA Pro 3 (2,600 W). But the number that matters for most people is how much of that you can actually fill with each brand’s own portable panels. By our math, that order flips:
- F3800 Plus: 3,200 W (eight Anker 400 W panels in the 2-series, 2-parallel layout Anker publishes for this station). That’s the full rating.
- S5000: about 1,600 W cold-weather-safe with four Anker 400 W panels on the high-voltage port, or about 2,400 W in warm weather if you add two more on the 60 V port.
- DELTA Pro 3: about 1,600 W cold-weather-safe with four EcoFlow 400 W panels (EcoFlow’s own three-in-series diagram reaches 2,000 W but runs over the 150 V input limit on cold days).
- Explorer 5000 Plus: about 876 W with two SolarSaga 500 X panels, because each Low-PV port stops at 10.5 A. Its 4,000 W High-PV port is built for rigid roof or ground strings, not folding panels.
We haven’t tested any of these four stations. Everything here comes from each brand’s published specs (checked Nov 16, 2026 unless noted) and our own arithmetic, which we show.
Safety first. High-PV inputs run at up to 165 V (Anker), 150 V (EcoFlow), and 450 V (Jackery) DC. That can injure or kill. Have a licensed electrician or solar installer design and connect any rigid roof or ground array, including disconnects and overcurrent protection. Never backfeed a house through a wall outlet. Hardwired or whole-home circuits go through a transfer switch or inlet installed by a licensed electrician (transfer switch guide).
The solar ports, side by side
| Jackery Explorer 5000 Plus | Anker SOLIX S5000 | EcoFlow DELTA Pro 3 | Anker SOLIX F3800 Plus | |
|---|---|---|---|---|
| Battery | 5,040 Wh LiFePO₄ | 5,024 Wh LFP | 4,096 Wh LFP | 3,840 Wh LFP |
| AC output | 7,200 W, 120/240 V | 4,500 W (8,000 W peak), 120/240 V | 4,000 W (8,000 W surge), 120/240 V | 6,000 W, 120/240 V |
| High-voltage solar port | 135–450 V, 15 A, 4,000 W | 16–165 V, 17 A, 2,000 W | 30–150 V, 15 A, 1,600 W | Two ports, each 11–165 V, 17 A, 1,600 W |
| Low-voltage solar port | Two ports, 16–60 V, 10.5 A each (600 W one port, 1,200 W both) | 11–60 V, 17 A, 1,000 W | 11–60 V, 20 A, 1,000 W | (both ports are 11–165 V) |
| Total solar on paper | 5,200 W | 3,000 W | 2,600 W | 3,200 W |
| Solar W per kWh of battery | ~1,032 | ~597 | ~635 | ~833 |
| Charge temperature | 32–113 °F | 32–104 °F | 32–113 °F | not listed on the page we checked |
Jackery: Explorer 5000 Plus page and Jackery support’s Explorer 5000 Plus Basic Information FAQ (checked Nov 14, 2026; details in our Explorer 5000 Plus solar input guide). Anker S5000: S5000 specs (“Solar Panel Input 1: 11 – 60V⎓17A Max (1,000W Max); Solar Panel Input 2: 16 – 165V⎓17A Max (2,000W Max)”; 5,024 Wh; 4,500 W; 97 lb; charging 32–104 °F), checked Nov 16, 2026. EcoFlow: DELTA Pro 3 page (“High-PV Input: 30V-150V, 15A, 1600W Max; Low-PV Input: 11V-60V, 20A, 1000W Max”; charging 32–113 °F), checked Nov 16, 2026. Anker F3800 Plus: F3800 Plus page (“11-165V ⎓ 17A Max (1600W Max Each)”), checked Nov 16, 2026. “Solar W per kWh” is our math (total solar ÷ battery kWh).
A few things the table doesn’t show:
- Jackery’s two ports work at the same time. Jackery’s roof-solar guide describes running a 4,000 W High-PV string and 1,200 W on the Low-PV side together.
- The S5000’s two ports are different. Port 1 is a 60 V port (like a smaller station’s). Port 2 is the high-voltage one. On the F3800 Plus, both ports are the same 165 V type, which is why it’s the easiest of the four to fill with portable panels.
- Anker’s F3800 Plus page warns that “exceeding 165V may cause damage to the solar input ports.” Treat every voltage ceiling here as a hard limit, including on the coldest sunny morning of the year, when panel voltage is highest.
What each brand’s own portable panels can actually deliver
This is where nameplate and reality split. Panel voltage rises as panels get colder, so a string that’s fine in July can go over a port’s limit on a sunny January morning. We check every layout at −4 °F (−20 °C).
| Station | Brand panels and layout | Panel watts used | Cold check (−4 °F) | Share of the station’s solar rating |
|---|---|---|---|---|
| F3800 Plus | 8 × Anker PS400 (400 W): 2 in series, 2 strings in parallel, on each port | 3,200 W | 132.3 V vs 165 V (assumed coefficient) | 100% |
| S5000, cold-safe | 4 × Anker PS400 in the same 2S2P layout on port 2 | 1,600 W | 132.3 V vs 165 V (assumed coefficient) | 53% |
| S5000, warm weather | + 2 × PS400 in parallel on port 1 | ~2,400 W | 57.6 V at 77 °F; ~66 V at −4 °F vs 60 V | 80% |
| DELTA Pro 3, cold-safe | 4 × EcoFlow 400W: 2 in series on High-PV + 2 in parallel on Low-PV | 1,600 W | 110.3 V vs 150 V; 55.1 V vs 60 V | 62% |
| DELTA Pro 3, EcoFlow’s manual example | 3 in series on High-PV + 2 in parallel on Low-PV | 2,000 W | 165.4 V vs 150 V (over) | 77% |
| Explorer 5000 Plus | 2 × SolarSaga 500 X, one per Low-PV port | ~876 W (port-current-limited) | 54.2 V vs 60 V | 17% |
Panel specs: Anker PS400, 57.6 V open-circuit, 48 V / 8.33 A operating (Anker PS400 page, checked Nov 16, 2026); Anker doesn’t publish a temperature coefficient for it, so we assume −0.33 %/°C (the steepest published figure among the panels we track). EcoFlow 400W, 48 V Voc, 41 V working, 11 A short-circuit, 9.8 A working, −0.33 %/°C (400W panel manual, checked Oct 20, 2026). SolarSaga 500 X, 48.5 V Voc, 41.7 V / 12.0 A operating, −0.26 %/°C (Jackery, checked Oct 20 and Nov 14, 2026). The F3800 Plus layout is from Anker’s F3800 Plus Technical Brief and Design Guide (V1.1). The DELTA Pro 3 layouts are from EcoFlow’s user manual and an Oct 22, 2026 EcoFlow support reply, both covered in our best panels for each station guide. Cold voltages and watts are our math.
What’s behind each row:
- F3800 Plus: two PS400s in series make about 96 V working and 115 V open-circuit, and two of those strings in parallel draw about 16.7 A, just under the 17 A limit. Four panels per port, two ports, 3,200 W. Anker’s own design guide shows this layout, so this is the one case here where the brand’s panels fill the whole rating.
- S5000 port 2 (16–165 V, 17 A, 2,000 W): it has the same voltage and current limits as each F3800 Plus port, so the same four-panel 2S2P layout fits by the numbers (about 1,600 W). Three in series would be 172.8 V open-circuit even at 77 °F, over 165 V. We didn’t find an S5000-specific wiring diagram from Anker on the pages we checked, so confirm with Anker before wiring.
- S5000 port 1 (11–60 V): a single PS400 is 57.6 V open-circuit at 77 °F, which leaves only about 4% of headroom. With a typical cold coefficient, it would pass 60 V somewhere around 47–54 °F. When we asked Anker about the same 57.6 V panel on a 60 V input (the C1000 Gen 2) in October, Anker said cold-weather voltage rise “could push the Voc closer to the upper limit” and recommended monitoring it in sub-freezing temperatures (details). For winter use, we’d put a lower-voltage panel set on port 1 (open-circuit well under 50 V), or leave it for warm months.
- DELTA Pro 3: EcoFlow’s manual shows three 400W panels in series on High-PV (144 V at 77 °F). With EcoFlow’s published coefficient, that string passes 150 V below about 54 °F. EcoFlow support told us the diagram “does not apply to all climate conditions” and recommended two in series for cold climates. That’s the 1,600 W row.
- Explorer 5000 Plus: each SolarSaga 500 X wants about 12.0 A at full output, but each Low-PV port stops at 10.5 A, so each panel tops out near 438 W. Jackery’s FAQ says the station supports no more than two 500 X panels. Four SolarSaga 200W panels (two in series per port) land in the same place, about 800 W. The rest of the 5,200 W needs a rigid High-PV string (how that string is sized).
How fast each one refills from solar
Our usual rule: battery Wh ÷ (solar watts × 0.85) = peak sun hours to go from empty to full. The 0.85 charge-path figure is our assumption, and real panels rarely make their label watts (why panels fall short). For a northern winter we also show Minneapolis December days at 2.89 peak sun hours a day (panels tilted 60°, NREL PVWatts typical year, from our winter solar guide).
| Station (base battery) | At full solar rating | With brand portable panels, cold-safe | Minneapolis December, brand panels | Energy per December day, brand panels |
|---|---|---|---|---|
| Explorer 5000 Plus (5,040 Wh) | 1.1 sun-hours (5,200 W) | 6.8 sun-hours (~876 W) | ~2.3 days | ~2.2 kWh |
| S5000 (5,024 Wh) | 2.0 sun-hours (3,000 W) | 3.7 sun-hours (1,600 W) | ~1.3 days | ~3.9 kWh |
| DELTA Pro 3 (4,096 Wh) | 1.9 sun-hours (2,600 W) | 3.0 sun-hours (1,600 W) | ~1.0 day | ~3.9 kWh |
| F3800 Plus (3,840 Wh) | 1.4 sun-hours (3,200 W) | 1.4 sun-hours (3,200 W) | ~0.5 day | ~7.9 kWh |
Our math from the port and panel figures above (research/sources-2026-11-16/flagship-solar-math.py). It assumes clear-sky-equivalent sun hours, panels aimed well, no shade, and no house loads drawing at the same time (running appliances while solar charges). “Energy per December day” = panel watts × 2.89 × 0.85.
The takeaway: in a winter outage, the solar you can actually hang on the station matters far more than the nameplate. With portable panels only, the F3800 Plus can bring in about twice the daily energy of the S5000 or DELTA Pro 3, and about 3.5 times the Explorer 5000 Plus. The flip side is that eight 400 W folding panels is a lot of panel to set out, aim, and put away. If you’re willing to mount a rigid array, the Explorer 5000 Plus’s 4,000 W High-PV port is the biggest of the four.
Prices on the official US stores (Nov 16, 2026)
| Station | Price | $ per kWh of battery | Status Nov 16 |
|---|---|---|---|
| Anker SOLIX S5000 | $2,599.99 (list $3,599.99) | ~$518 | Pre-order; Anker’s page says orders placed on or after Nov 6 ship in 9–10 weeks; Black Friday pricing through Nov 18 |
| Anker SOLIX F3800 Plus | $2,399.99 after Anker’s Black Friday code (store price $2,999.99) | ~$625 | Sold out |
| EcoFlow DELTA Pro 3 | $2,799 (list $3,299) | ~$683 | Standalone unit unavailable on EcoFlow’s store feed |
| Jackery Explorer 5000 Plus | $3,499 (station only) | ~$694 | Station alone unavailable; the 10 kWh version with one Battery Pack 5000 Plus was $6,199 and in stock |
Brand panels, same day: Anker PS400 $699.99 (sold out), EcoFlow 400W $699 or $2,499 for four (unavailable), Jackery SolarSaga 500 X $999 (sold out), Jackery SolarSaga 200W $429 (Dune color in stock).
Price update, Nov 22, 2026: the Anker SOLIX F3800 Plus Black Friday code has ended; it is back to its $2,999.99 store price (about $781 per kWh) and now in stock. The S5000 is $2,499.99 (pre-order, about $498 per kWh). The DELTA Pro 3 and Explorer 5000 Plus prices above were unchanged.
Anker prices from each product page’s structured data and Black Friday banner; EcoFlow and Jackery from their US stores’ product listings. All checked Nov 16, 2026. ”$ per kWh” is our math on the base battery only. Prices and stock change often around Black Friday (Nov 27) and Cyber Monday (Nov 30), so check at checkout. More in our Black Friday power station deals judged for solar and cost per kWh comparison.
Which one fits your solar plan
- You’ll only ever use folding panels and want the most winter solar: the F3800 Plus is the only one of the four whose rating you can fill with the brand’s own portable panels, if you can find it in stock and don’t mind setting out eight panels.
- You want a 5 kWh battery and a lower price per kWh: the S5000 has the lowest price per kWh here right now, but it’s a pre-order with a long ship time. Plan on about 1,600 W of portable solar in winter, more in summer.
- You’re already in EcoFlow’s system: the DELTA Pro 3 lands near the S5000 on portable solar (about 1,600 W cold-safe). Don’t copy the three-in-series diagram if you charge in cold weather.
- You have or will build a rigid roof or ground array: the Explorer 5000 Plus’s 135–450 V, 4,000 W High-PV port is the strongest of the four. With folding panels alone, plan on well under 1,000 W. Already have roof solar? See does rooftop solar work in a power outage? for which of these inputs a typical rooftop string actually fits.
Not sure how much capacity you need in the first place? Start with the runtime calculator and the 3-day outage plan with solar. For the non-solar side of these units (output, 240 V, expansion, cycle life), see home backup flagships compared.
The StormWatts owner has an Explorer 5000 Plus kit on order. Once it arrives, we’ll add owner-reported solar readings to our Explorer 5000 Plus guide, clearly labeled as owner-tested. Nothing on this page comes from hands-on testing.
Products mentioned
- Jackery Explorer 5000 Plus, Battery Pack 5000 Plus, SolarSaga 500 X, SolarSaga 200W
- Anker SOLIX S5000, Anker SOLIX F3800 Plus, Anker SOLIX PS400
- EcoFlow DELTA Pro 3, EcoFlow 400W Portable Solar Panel
Sources
- Anker SOLIX, S5000 specs page (solar inputs, capacity, output, weight, charging temperature, 10,000 cycles) and S5000 product page ($2,599.99 pre-order, shipping update, Black Friday window) (checked Nov 16, 2026)
- Anker SOLIX, F3800 Plus (11–165 V, 17 A, 1,600 W per input; 3,200 W; $2,399.99 after code; sold out) and PS400 Portable Solar Panel (57.6 V Voc, 48 V / 8.33 A; $699.99, sold out) (checked Nov 16, 2026); F3800 Plus Technical Brief and Design Guide V1.1 (checked Oct 20, 2026)
- EcoFlow US, DELTA Pro 3 (High-PV 30–150 V, 15 A, 1,600 W; Low-PV 11–60 V, 20 A, 1,000 W; $2,799) and 400W Portable Solar Panel ($699; 4-pack $2,499) (checked Nov 16, 2026); DELTA Pro 3 user manual and 400W panel manual (checked Oct 20, 2026)
- Jackery US, Explorer 5000 Plus listings ($3,499 station; $6,199 10 kWh), SolarSaga 500 X ($999, sold out), SolarSaga 200W ($429) (checked Nov 16, 2026); Explorer 5000 Plus Basic Information FAQ and roof-solar blog (checked Nov 14, 2026)
- NREL/NLR PVWatts V8 Minneapolis typical-year December sun hours, as used in our winter solar guide (queried Oct 23, 2026)
- StormWatts math:
research/sources-2026-11-16/flagship-solar-math.py(+.out.txt); the 0.85 charge-path efficiency and the −0.33 %/°C coefficient for the Anker PS400 are our assumptions, labeled above